En-suite installation in Hanley

For HMO en-suite installation in Hanley, we survey the property, plan each bedroom and escape route to licensing standards, then build to a fixed price for the agreed specification.

We cover Hanley and the surrounding Staffordshire postcodes, including ST1.

  • Covering Hanley and nearby Staffordshire towns
  • Work by S&K and vetted subcontractors
  • Free survey and fixed written quote

Ask about a house in Hanley

Tell us about the property. We reply within one working day.

HMO projects in Hanley are shaped by the rules of Stoke-on-Trent City Council. Before we price anything, we check whether the address falls within an additional licensing scheme or an Article 4 direction, because both change what the house needs and how long it takes.

We cover ST1 and the neighbouring postcodes, with the same standards in Hanley as anywhere else in Staffordshire.

HMO rules in Stoke-on-Trent City Council

RuleStoke-on-Trent City Council
Mandatory HMO licence (5+ people)In force everywhere in England
Additional HMO licensingProposed
A citywide scheme was proposed in August 2026, subject to consultation
Selective licensingNot confirmed
Article 4 direction for small HMOsIn force
Whole city, immediate direction from 23 October 2026. It lapses unless the council confirms it within six months

Checked October 2026 against Stoke-on-Trent City Council's HMO licensing page. Schemes change, so we confirm the position for your address before any work starts.

Stoke-on-Trent City Council has an Article 4 direction across its whole area, so turning a family house in Hanley into a small HMO needs planning permission. This is an immediate direction that took effect on 23 October 2026 and lapses unless the council confirms it within six months. We prepare the planning application before any conversion work starts. Seven or more occupants always needs planning permission. Stoke-on-Trent City Council proposed a citywide additional licensing scheme in August 2026, subject to consultation, so smaller HMOs may need a licence in future.

Our HMO en-suite installation service in Hanley

We fit en-suite shower rooms in HMO bedrooms across Hanley, starting with a check that each bedroom still meets its size standard once the en-suite is built. Councils take different views on whether en-suite floor area counts, so we confirm the local position first.

Older houses often have joists running the wrong way and soil stacks in fixed positions, so in Hanley we check the drainage route under the floor before quoting. Every en-suite we fit in Staffordshire is finished with a ducted fan, certified electrics and fire stopping.

  • Bedroom measured to confirm it still meets size standards
  • Shower, toilet, basin and wipe-clean wall finish fitted
  • Drainage route checked under the floor at survey
  • Extract fan ducted to outside with overrun control
  • Electrical work tested and certified

Sharer demand in Hanley

Hanley is close to a university or college campus, so students and young professionals are part of the local rental market. If that is your market, layouts with en-suites, a generous kitchen and secure bike storage are worth planning in from the start.

En-suite installation near Hanley

En-suite installation in Hanley: common questions

Do you supply fire doors and alarms as part of a conversion?

Yes. Fire doors, the alarm system and emergency lighting are specified to the fire risk of the house and included in the price, not added later.

Do I need planning permission to convert a house to an HMO in Hanley?

It depends on the number of occupants and whether Stoke-on-Trent City Council has an Article 4 direction covering the address. Seven or more occupants always needs planning permission. We check the position for your street before quoting.

What size must bedrooms be in an HMO in Hanley?

For licensed HMOs in England a room for one adult must be at least 6.51 square metres and a room for two adults at least 10.22 square metres. Stoke-on-Trent City Council may set additional standards, which we design to.

Can you convert part of a building above a shop in Hanley?

Often, yes. Flats above shops need extra attention to fire separation from the commercial unit, and we assess this at survey stage.

Need HMO en-suite installation help in Hanley?

Send us the address and we'll check the licensing and planning position before we talk about prices.

Call free Guide price